Diagnomatic

  • Contrast details mammography phantom according to European Protocol for quality assurance in Digital Mammography. It can be used to determine if mammographic images indicate objects with very low contrast and very small diameter, to find out the optimum exposure technique, or to compare image quality at various object thicknesses by varying the PMMA thickness.
  • Upgraded contrast details mammography phantom according to European Protocol for quality assurance in Digital Mammography. It can be used to determine if mammographic images indicate objects with very low contrast and very small diameter, to find out the optimum exposure technique, or to compare image quality at various object thicknesses by varying the PMMA thickness.
  • Phantom Pro-MAM BR is designed for precise assessment of AEC system performance in accordance with American College of Radiology and MQSA recommendations. Unlike acrylic, these testing slabs are manufactured with very tight thickness tolerances and more accurately simulate real breast tissue over the range of energies used in mammography. Pro-MAM BR (50% glandular / 50% adipose) is most commonly used.
  • Calibrated scale for assessment of the breast compression force of mammography systems.
  • This phantom was designed to provide a fast and easy way to test image quality on digital biopsy mammography units and qualify for ACR accreditation.
  • The Pro-MAM HCRP includes a bar pattern to evaluate the resolution in the range of 5.0 - 20.0 LP / mm (13 groups). It has been embedded in a polycarbonate sheath to protect it from wear or damage.
  • The phantom for performance testing of mammography X-ray units. It has 49 holes that generate subtle changes in contrast. It can be used to detect small variations in system’s performance.
  • This test device was developed to provide the user with a convenient, quick and accurate way of testing collimation of mammography units. It is very simple to use. Instead of using all those hard-to-find coins, you only use our test tool.
  • The phantom designed to be used for routine quick and ongoing checks of imaging performance of mammography systems. It allows evaluating particularly those aspects which are most liable to deterioration
  • Set of acrylic plates for testing Automated Exposure Control of mammography systems.
  • Test grid for testing mammography-cassette film-screen contact.
  • 21 step aluminium wedge for determination of the dose reproducibility and sensitometric curve shape, speed and mid-gradient of mammography X-ray film.
  • With more than 15 years of experience in healthcare imaging quality assurance, we designed DIAGNOMATIC a hardware and software solution which simplifies the process using automatic, certified, and cloud-based data analysis.
  • The Pro-CT mk II phantom can be used for carrying out acceptance and constancy tests of computed tomography systems according to IEC 61223-3-5 and the AAPM (American Association of Physicists in Medicine) guidelines.
  • The phantom used for AEC testing on CTs. All mounting and positioning features are the same as in the Pro-CT mk II phantom allowing for off-the-table measurement.
  • The Pro-CT MINI phantom is a compact CT image quality testing solution. When connected with Pro-CT Dose it may be used for carrying out acceptance and constancy tests of computed tomography systems according to IEC 61223-3-5 and the AAPM (American Association of Physicists in Medicine) guidelines.
  • The Pro-CT AAPM phantom can be used for carrying out tests of computed tomography systems according to Report no. 1 of the AAPM (American Association of Physicists in Medicine).
  • Set of homogenous cylinders designed to image paediatric and adult head and body. Used for CTDI measurement and to separate dose information for each.
  • The Pro-CT AAPM phantom can be used for carrying out tests of computed tomography systems according to Report no. 1 of the AAPM (American Association of Physicists in Medicine).
  • This phantom is designed according to ICRU 87 report and AAPM TG-200 specifications.
  • This phantom is designed according to AAPM TG-111 findings. The phantom comprises three 20 cm thick PMMA cylinders 300 mm in diameter similar to the standard Pro-CT Dose phantom.
  • The phantom for performance evaluation of small animal systems or ultra-high resolution ECT systems.
  • The phantom for NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters). It can be used to evaluate, for example: center-of-rotation error, non-uniformity artifacts, changes of radius-of-rotation on spatial resolution, reconstruction filters on spatial resolution, attenuation and scatter compensation.
  • The phantom for small FOV NM and PET systems performance evaluation (collimator, artifacts, calibration, reconstruction parameters)