Products

  • The phantom for acceptance and constancy testing of Cone-Beam CT / Volume Tomography (DVT) in fluoroscopy according to DIN 6868-150.
  • The radiopaque ruler in the image provides a permanent reference of image size. It can be used to check the accuracy and position of the light field for quality control and adjustment as well as be included during x-ray procedures, leaving a clear measurement right on the x-ray image itself.
  • A spacer plate with adjustable legs for positioning Pro-Alpha and Pro-Digi test phantoms near the X-Ray tube on units without insertion slots (e.g. over-table / under-table tubes, C-arms etc.).
  • A set of simple tools dedicated for measurements on tomography X-Ray equipment. It can be used for the layerheight adjustment and tomography movement tests.
  • Simple to use and economic tool to perform true spatial alignment and coincidence tests on IGRT systems. Pro-RT Align-Cube contains engraved markings on the exterior and radiographic markers inside. The isocenters of both the OBI and the EPID can be checked for true spatial alignment and coincidence with that of the treatment beam. ‍The phantom ensures the accuracy of linacs’ image-guidance systems, including CBCT, x-ray volumetric imaging (XVI) and on-board imaging (OBI). It can be used to test: 3D cone beam registration kV and MV system coincidence kV and MV projection images laser and light field coincidence weekly remote table adjustments
  • This phantom is designed for quality control of a CT simulator, which usually consists of a CT scanner, virtual symulator software and a laser marking device (marking the centre of target volume). Since geometrical planning is the core of CT simulation, periodic quality control is essential for maintaining optimum image quality and patient care. The phantom allows performing detailed geometry and table movement tests as well as image quality assessment - low contrast resolution and high contrast detectability.
  • The Pro-RT ED phantom is used to account for tissue heterogeneity in radiotherapy treatment planning. It can be used to define the precise correlation of CT data to the electron density of various tissues. The phantom consists of two nested disks that represent the head and abdomen. Nine different tissue equivalent electron density plugs can be positioned at 17 different locations within the scan field. Included is a water vial plug that can be filled with any fluid. Optional distance marker plugs enable quick assessment of the CT scanner’s distance measurement accuracy.
  • Pro-RT IsoBeam This is a multifunctional, precision quality assurance tool for daily, weekly or monthly quality assessments of all mechanical and geometrical treatment parameters of linear accelerators or teletherapy units. It is designed to easily and accurately check collimator isocentricity, gantry isocentricity, table isocentricity, collimator field size accuracy, radiation/light field congruence, isocenter rotational stability, ODI accuracy and laser light alignments.
  • The Pro-Slit phantom is the so-called slit camera for accurate measurement of the focal spot size according to IEC 60336:2020. Its main advantages are repeatability, accuracy and possibility to measure the size of any focal spot.
  • With Pro-Star test Patterns focal spot size can be determined by observing the regions of blurring which occur when the pattern is radiographed by an x-ray source of finite dimensions.
  • Designed for administering Yttrium-90, Strontium-89, Phosphorous-32 and other beta emitting radiopharmaceuticals. The lightweight shield is manufactured in acrylic with a thin layer of lead encapsulated in the acrylic. This construction attenuates both beta emissions and Bremstrahlung.
  • The Pro-Tec™ PET Syringe Shield reduces hand exposure from syringes containing 511 keV radionuclides. The barrel of the shield is constructed of .34″ thick tungsten that attenuates FDG F-18 by 88%. The syringe shield is offered with or without a high density (5.6) flush mounted lead glass window.
Go to Top