  • The Cardiac Insert is designed to be used with the various Data Spectrum circular and elliptical cylinders, the Elliptical Lung-Spine Body Phantom, and the Anthropomorphic Torso Phantom.
  • The Anthropomorphic Torso Phantom includes a large, body-shaped cylinder with lung, liver, and spine features. The lung inserts can be filled with polystyrene beads and water to simulate lung tissue density. The product simulates the upper torso of an average to large person and also depicts the anatomical structures and radioactivity distributions.
  • This phantom is designed according to AAPM TG-111 findings. The phantom comprises three 20 cm thick PMMA cylinders 300 mm in diameter similar to the standard Pro-CT Dose phantom.
  • This phantom is designed according to ICRU 87 report and AAPM TG-200 specifications.
  • The Pro-CT AAPM phantom can be used for carrying out tests of computed tomography systems according to Report no. 1 of the AAPM (American Association of Physicists in Medicine).
  • Set of homogenous cylinders designed to image paediatric and adult head and body. Used for CTDI measurement and to separate dose information for each.
  • The Pro-CT AAPM phantom can be used for carrying out tests of computed tomography systems according to Report no. 1 of the AAPM (American Association of Physicists in Medicine).
  • The Pro-CT MINI phantom is a compact CT image quality testing solution. When connected with Pro-CT Dose it may be used for carrying out acceptance and constancy tests of computed tomography systems according to IEC 61223-3-5 and the AAPM (American Association of Physicists in Medicine) guidelines.
  • The phantom used for AEC testing on CTs. All mounting and positioning features are the same as in the Pro-CT mk II phantom allowing for off-the-table measurement.
  • The Pro-CT mk II phantom can be used for carrying out acceptance and constancy tests of computed tomography systems according to IEC 61223-3-5 and the AAPM (American Association of Physicists in Medicine) guidelines.
  • The CTP698 and CCT162 Lung Phantoms were designed for performing comparative measurements between CT scanners as part of the COPDGene® Study.
  • The Liver Phantom combines the advantages of objective test objects and anthropomorphic elements for evaluation of advanced iterative processing. The phantom includes low contrast test objects designed both for ROC tests along with conventional patterns, metal artifact inserts, and beads for MTF calculations.