  • This module can be used as a standalone in air or in water if mounted in the Pro-NM Performance cylinder. It can be used to evaluate changes of radius-of rotation on spatial resolution, spatial resolution measurement in air and in water, quantitative evaluation of reconstruction filters and scatter compensation methods.
  • ECT Line Source Phantom (SMR355) The ECT Line Source Phantom is a cylindrical, liquid filled container with 3 line source inserts.
  • The NEMA SPECT Triple Line Source Phantom is designed in accordance with the recommendations by the National Electrical manufacturers Association (NEMA) to standardize the measurement of reconstructed spatial resolution of SPECT
  • The Nema Scatter Phantom is designed in accordance with the recommendations by the National Electrical Manufacturers Association (NEMA) to standardize the measurement of count rate performance of a scintillation camera in the presence of scatter.
  • The PET scatter phantom is an acceptance testing tool used to determine the imaging systems relative sensitivity to scatter radiation. It can be used to measure the effects of dead-time and the effects of random events generated at different levels of activity of the line source.
  • The NEMA PET Sensitivity Phantom is designed in accordance with the recommendations by the National Electrical manufacturers Association (NEMA) to standardize the measurement of performance of PET. The product contains six concentric aluminum tubes used to detect camera sensitivity in PET.
  • The PET sensitivity phantom is used to measure the sensitivity or ability of positron emission tomographs to detect positrons. The phantom used for this purpose is a set of five metal tubes with a similar wall thickness.
  • The NEMA 94 PET Phantom consists of 1 large outer cylinder, 2 smaller fillable cylinders, 1 solid PTFE cylinder, and 3 stainless steel line sources.
  • Main application of Pro-NM NEMA 94 is PET acceptance testing with NEMA standard. Evaluation of count rate, uniformity, scatter fraction, attenuation compensation, and scatter compensation of ECT systems.
  • The NEMA IEC PET Body Phantom Set is designed in accordance with the recommendations by the National Electrical Manufacturers Association (NEMA) to standardize the measurement of performance of PET.
  • The phantom for evaluating performance of positron emission tomographs (PET). Recommended for use in the evaluation of reconstructed image quality in whole body PET imaging.
  • The Mini Deluxe phantom is a preclinical product that has both SPECT and PET capabilities. The phantom helps with spatial resolutions and mis-calibration.