Ge-68 Line Source and Cylindrical Phantoms for Siemens Healthineers SPECT, PET and PET/CT Systems
Brand | Epsilon |
Categories | PET-CT Sources |
Line
Sources – Siemens
Ge-68 line
sources are double layered tubes and made of high quality stainless steel. Each
line source is sealed on its ends by the process of precise argon welding.
Thanks to the argon welding process, the possibility of activity leakage is
eliminated, ensuring safe use of line sources.
Source related
information including product code, isotope type, activity, serial number and
production date is permanently marked with laser for traceability.
Uniformity
Each line
source is tested with 5 mm steps of scannings throughout its length for
uniformity.
The uniformity
of the line sources is within +/- 5% limits.
GE-68
Cylindirical Phantom – Siemens
Ge-68
Cylindirical phantoms are used for 2D and 3D normalization and in test images
of PET and PET-CT systems. Radioactive element is uniformly filled in the
cylindrical cast. Each cylindrical phantom manufactured is checked with a
PET-CT scanner to ensure high quality.
The results of quality control image files are available upon request.
Siemens Healthineers Solutions |
Product Code |
Product Type |
Isotope |
Activity |
Quantity |
Replacement Period* |
System Model |
SI |
|||||
BIOGRAPH |
||||||
Initial Set-up & Annual Replacement |
FNT1010 |
Phantom |
Ge-68 |
44 MBq |
1 |
1 Year |
CBK1020 |
Line Source |
Ge-68 |
37 MBq |
2 |
1 Year |
|
TST1030 |
Test Tube |
Ge-68 |
5.5 kBq |
1 |
1 Year |
|
BIOGRAPH PICO |
||||||
Initial Set-up & Annual Replacement |
FNT1014 |
Phantom |
Ge-68 |
74 MBq |
1 |
1 Year |
CBK1020 |
Line Source |
Ge-68 |
37 MBq |
2 |
1 Year |
|
TST1031 |
Test Tube |
Ge-68 |
15 kBq |
1 |
1 Year |
|
BIOGRAPH TRUE V & mCT & Horizon |
||||||
Initial Set-up & Annual Replacement |
FNT1012 |
Long Phantom |
Ge-68 |
74 MBq |
1 |
1 Year |
CBK1020 |
Line Source |
Ge-68 |
37 MBq |
1 |
1 Year |
|
TST1031 |
Test Tube |
Ge-68 |
15 kBq |
1 |
1 Year |
|
Initial Set-up & Annual Replacement |
FNT1013 |
Long Phantom |
Ge-68 |
92.5 MBq |
1 |
1 Year |
CBK1020 |
Line Source |
Ge-68 |
46.25 MBq |
1 |
1 Year |
|
TST1031 |
Test Tube |
Ge-68 |
15 kBq |
1 |
1 Year |
Siemens Healthineers Solutions |
Product Code |
Product Type |
Isotope |
Activity |
Quantity |
Replacement Period* |
System Model |
SI |
|||||
BIOGRAPH 450 Vision |
||||||
Initial Set-up & Annual Replacement |
FNT1012 |
Long Phantom |
Ge-68 |
92.5 MBq |
1 |
1 Year |
CBK1020 |
Line Source |
Ge-68 |
46.25 MBq |
1 |
1 Year |
|
TST1031 |
Test Tube |
Ge-68 |
15 kBq |
1 |
1 Year |
|
BIOGRAPH 600 Vision |
||||||
Initial Set-up & Annual Replacement |
FNT1015 |
Long Phantom |
Ge-68 |
111 MBq |
1 |
1 Year |
CBK1020 |
Line Source |
Ge-68 |
46.25 MBq |
2 |
1 Year |
|
TST1031 |
Test Tube |
Ge-68 |
15 kBq |
1 |
1 Year |
|
BIOGRAPH mMR |
||||||
Initial Set-up & Annual Replacement |
FNT1015 |
Long Phantom |
Ge-68 |
111 MBq |
1 |
1 Year |
CBK1025 |
Line Source |
Ge-68 |
55 MBq |
4 |
1 Year |
|
TST1031 |
Test Tube |
Ge-68 |
15 kBq |
1 |
1 Year |