Dosimeters perform monitoring and measurement of personal dose equivalent and personal dose equivalent rate in the wide energy range – from the natural background level up to 5-10 Sv/h (500-1000 R/h). Instruments are stable to dose up to 300 Sv, have two thresholds in DER and DE ranges, have non volatile memory for data storage. Hermetic, water-resistant and shockproof case and the fluorescent backlight on LCD screen allow to use instruments in harsh and extreme conditions.

Brand

Model

PM1604A

Add to Quote

PM1604A models are energy-compensated personal dosimeters of pocket size that measure personal dose equivalent (DE) and personal dose equivalent rate (DER) of both gamma and X-ray radiation. Dosimeters have two alarm thresholds. If the pre-set dose and dose rate thresholds are exceeded, instruments immediately alert the user through an audible alarm. Dosimeters store up to 1000 events in non-volatile memory and transmit all recorded data via infrared channel to a PC for further processing and analysis.

Dosimeters may be used independently or as a part of a system for efficient and emergency monitoring of personnel and people at production facilities and other sites with external X-ray and gamma radiation sources.

PM1604A dosimeters are recommended for emergency services, customs and border patrol, radiological and radioisotope laboratories, medical professionals, personnel of nuclear facilities, civil defence, firefighters and police.

Detector Geiger-Muller tube
Dose indication range 0.01 μSv – 9.99 Sv
Dose measurement accuracy ± 15 %
Dose rate indication range 0.01 μSv/h – 6.50 Sv/h
Dose rate measurement accuracy ±(15 + К1/Ḣ+ К2Ḣ) %, where Ḣ = DER value, mSv/h; К1 = coefficient equal to 0.02 (mSv/h); К2 = coefficient equal to 0.003 (mSv/h)-1
Energy range 0.048 – 6.0 МeV
Energy response relative to 0.662 MeV (137Cs)
137Cs, 0.048 – 3.0 МeV ± 30 %
137Cs, 3.0 – 6.0 МeV ± 50 %
Alarms audible
PC communication IR adapter
Power supply (2.95 ± 0.25)V (one battery, type CR2032)
Additional functions Clock-calendar mode (time, date), timer mode (set of time intervals) , stop-watch mode (measurement of time intervals)
Battery lifetime using LCD backlight not more than 5 s/day, audible alarm – not more than 20 s/day and at an average value of the measured DER up to 0.3 μSv/h, at least 9 months
Ingress protection IP67
Drop test 1.5 m
Dimensions 50х56х19 mm; 50x90x19 mm – with a clip
Weight 0.085 kg
Operating temperature -20 up to +70 °C (from -4 up to +158 °F)
Atmospheric pressure from 84 up to 106.7 kPa Humidity up to 98% at 35°C (95°F)
Mean service lifetime 10 years

Features

PM1604A dosimeters are recommended for emergency services, customs and border patrol, radiological and radioisotope laboratories, medical professionals, personnel of nuclear facilities, civil defence, firefighters and police.

Specifications

Detector Geiger-Muller tube
Dose indication range 0.01 μSv – 9.99 Sv
Dose measurement accuracy ± 15 %
Dose rate indication range 0.01 μSv/h – 6.50 Sv/h
Dose rate measurement accuracy ±(15 + К1/Ḣ+ К2Ḣ) %, where Ḣ = DER value, mSv/h; К1 = coefficient equal to 0.02 (mSv/h); К2 = coefficient equal to 0.003 (mSv/h)-1
Energy range 0.048 – 6.0 МeV
Energy response relative to 0.662 MeV (137Cs)
137Cs, 0.048 – 3.0 МeV ± 30 %
137Cs, 3.0 – 6.0 МeV ± 50 %
Alarms audible
PC communication IR adapter
Power supply (2.95 ± 0.25)V (one battery, type CR2032)
Additional functions Clock-calendar mode (time, date), timer mode (set of time intervals) , stop-watch mode (measurement of time intervals)
Battery lifetime using LCD backlight not more than 5 s/day, audible alarm – not more than 20 s/day and at an average value of the measured DER up to 0.3 μSv/h, at least 9 months
Ingress protection IP67
Drop test 1.5 m
Dimensions 50х56х19 mm; 50x90x19 mm – with a clip
Weight 0.085 kg
Operating temperature -20 up to +70 °C (from -4 up to +158 °F)
Atmospheric pressure from 84 up to 106.7 kPa Humidity up to 98% at 35°C (95°F)
Mean service lifetime 10 years

Measurements