Radiation Alert GammaView Monitor
The compact GammaView is light, easy to carry and operate with a 1×1 Nal scintillation detector that accurately measures gamma contamination and exposure. Perfect for use in the lab, facility, and in the field. The GammaView can also be used as a single-channel analyzer (SCA).
Brand | |
---|---|
Model | GammaView |
The compact GammaView is light, easy to carry and operate with a 1×1 Nal scintillation detector that accurately measures gamma contamination and exposure. Perfect for use in the lab, facility, and in the field.
The GammaView can also be used as a single-channel analyzer (SCA). This function allows a “window” to be set to focus on a specific energy region of the gamma spectrum, effectively reducing the background count.
Features Included Adjustable Timer, Selectable Alert, On-board Memory, Bluetooth, Free Software
Gamma Scintillator Detector
1×1 NaI Scintillation Probe. 2.5 cm (1 in) dia. x 2.5 cm (1 in) thick with C Connector
The GammaView is optimized for use with the included 1×1 NaI probe.
Or, optional 2×2 NaI(Tl) scintillator, 5.1 cm (2 in.) dia. x 5.1 cm (2 in.) thick
Operating Range
mR/hr – 1 μR/h to 5 mR/h
μSv/hr – 0.001 to 50
CPM – 0 to approx. 875,000
CPS – 0 to approx. 14,584
Total Counts- 999,999
Energy Range
20 Kev to 1.5 MeV
Typical sensitivity
150 CPM/µR/hr.
Gamma Scintillator Detector
Accuracy
±10% with Source Calibration (Referenced to Cs137)
Operating Voltage
Typically 500 to 1200 Volts
Selectable Alert Set Range
mR/hr – 1 μR/h to 5 mR/h
μSv/hr – 0.001 to 50
CPM – 1 to 875,000
CPS- 1 to 14,584
Pulsating beeper sounds the alert.
Display
Graphic Display with Backlight
Averaging Periods
Display updates every 3 seconds. At low background levels, the update is the average for the past 30-second time period. The timed period for the average decreases as the
radiation level increases
Size Base unit – 140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.), Probe- 5.0 X 18.5 cm (2 x 7.3 in) Weight Base unit – 193 grams (6.8 oz) with batteries. Probe- 393 grams (13.8 oz)
Features
Features Included Adjustable Timer, Selectable Alert, On-board Memory, Bluetooth, Free Software
Specifications
Gamma Scintillator Detector
1×1 NaI Scintillation Probe. 2.5 cm (1 in) dia. x 2.5 cm (1 in) thick with C Connector
The GammaView is optimized for use with the included 1×1 NaI probe.
Or, optional 2×2 NaI(Tl) scintillator, 5.1 cm (2 in.) dia. x 5.1 cm (2 in.) thick
Operating Range
mR/hr – 1 μR/h to 5 mR/h
μSv/hr – 0.001 to 50
CPM – 0 to approx. 875,000
CPS – 0 to approx. 14,584
Total Counts- 999,999
Energy Range
20 Kev to 1.5 MeV
Typical sensitivity
150 CPM/µR/hr.
Gamma Scintillator Detector
Accuracy
±10% with Source Calibration (Referenced to Cs137)
Operating Voltage
Typically 500 to 1200 Volts
Selectable Alert Set Range
mR/hr – 1 μR/h to 5 mR/h
μSv/hr – 0.001 to 50
CPM – 1 to 875,000
CPS- 1 to 14,584
Pulsating beeper sounds the alert.
Display
Graphic Display with Backlight
Averaging Periods
Display updates every 3 seconds. At low background levels, the update is the average for the past 30-second time period. The timed period for the average decreases as the
radiation level increases
Measurements
Size Base unit – 140 X 68 X 33 mm (5.5 X 2.7 X 1.3 in.), Probe- 5.0 X 18.5 cm (2 x 7.3 in) Weight Base unit – 193 grams (6.8 oz) with batteries. Probe- 393 grams (13.8 oz)