CBCT-150 phantom is used for constancy testing of CBCT systems.
CT AEC (Computed Tomography Automatic Exposure Control) phantom is used for constancy testing of CT AEC systems.
Suitable for both kV and MV energies, CTTE is a tissue equivalent phantom consisting of a water equivalent nested head and body phantom each with 8 holes to house interchangeable inserts of different tissue equivalent materials
Holder for Leeds Test Objects’ TO CTDI & TO CTDI plus phantoms, which enables hanging of the TO CTDI off the edge of its carry case. The holder has been carefully designed to allow for suspension of the phantom over the couch end, ensuring balance and rigidity.
TO CTDI plus permits the user to measure the dose index for computed tomography systems. The test object consists of three PMMA cylinders, one cylinder represents the paediatric head (100mm diameter), the second the adult head (160mm diameter) and the other represents the body (320mm diameter). The length of each cylinder is 140mm. Each cylinder contains holes large enough to accept a radiation detector, used to take the dose measurements.
The TO CTIQ Image Quality phantom is designed for use with CT (Computed Tomography) units. TO CTIQ comprises a PMMA cylinder with recesses to house test inserts, and has been designed to nest within the TO CTDI body.
The SedentexCT DI dose index phantom comprises a stack of PMMA plates forming a cylinder representing the adult head.
The Catphan® 500 provides complete characterization of maximum imaging performance for axial and spiral CT scanners. The Catphan® 500 provides a comprehensive set of measurements to measure the maximum performance of your CT scanner’s sensitometry, uniformity, geometric and low-contrast sensitivity.
The Catphan® 605 provides a compact, inexpensive phantom with a basic suite of tests to measure maximum performance characteristics of multi-slice CT's and other state of the art scanners. The Catphan® 605 has enhanced measurement capabilities for precise measurement of thin slices and higher resolutions found in modern multi-slice scanners.
The Catphan® 700 is intended for use with state of the art CT scanners and research that require an advanced phantom to measure their full potential.
Catphan annuli are cast from uniformity material. Annuli are available in a variety of round and oval sizes and mimic the attenuation of patients and their effect on image quality. All annuli are designed to be slipped over 20cm OD Catphan phantoms.